Commit Graph
9 Commits
Author SHA1 Message Date
ddidderr e62f584377 chore(lints): enforce per-crate lint policy and add build profiles
Give every member crate its own `[lints.clippy]` (`pedantic`, `todo`,
`unwrap_used`) and `[lints.rust]` block, add explicit `release` and
`production` profiles to the workspace manifest, and fix the code so that
`just clippy` -- `cargo clippy --workspace --all-targets --all-features
-- -D warnings` -- passes with zero warnings.

Declaring the lints is the easy half and on its own it was actively
harmful: `unsafe_code = "forbid"` cannot be overridden from source, so it
broke `lanparty-gateway`, `lanparty-client-tap`, and
`lanparty-client-route`, which all need OS FFI, and the workspace no
longer compiled on Linux at all. The rest of the workspace produced
roughly 120 denied lints. A lint policy nobody can satisfy is worse than
no policy, so this commit makes the tree actually clean.

Unsafe policy: the three FFI crates use `unsafe_code = "deny"`, and the
one module in each that holds the FFI (`gateway::packet`,
`client_tap::windows`, `client_route::windows`) opts back in with a
documented `#![allow(unsafe_code)]`. Every other crate keeps `"forbid"`.
`deny` was chosen over dropping the lint so that `unsafe` outside those
modules is still a hard error, and over per-block allows because the FFI
is dense enough that per-block attributes would drown the code.

Build profiles: `release` stays optimized but debuggable (debug info,
debug assertions, overflow checks, no LTO, incremental) so that a bug
reproduced at close-to-real speed still panics loudly and gives a usable
backtrace. `production` inherits from it and turns all of that off, adding
fat LTO and a single codegen unit, and is what ships. Note the
consequence: `cargo build --release` binaries are now slower than before
this commit and must not be shipped; use `just build-production`.

Code changes made to satisfy the lints, grouped by kind:

- `# Errors` sections on every public fallible function, and `# Panics`
  on `RoomRegistry::new`. The Windows-only implementations and their
  non-Windows `bail!` stubs are documented in parallel so the crates stay
  clean when built for Windows too, which CI on Linux cannot check.
- Panicking paths removed rather than documented where the panic was only
  an unreachable invariant: `OverlayHeader::decode` and
  `declared_payload_len` take a fixed-size prefix via `first_chunk`
  instead of `try_into().expect(...)`, and `RoomRegistry::join` returns an
  `InternalError` reject instead of `expect`ing the room it just inserted.
- Tests keep using `unwrap`/`unwrap_err`: each crate root carries
  `#![cfg_attr(test, allow(clippy::unwrap_used))]`. The lint is about
  production code; an `expect` message per assertion buys nothing.
- Lossy casts replaced with `try_from` where a real conversion was
  happening (datagram-size negotiation, control-frame length prefix,
  MTU clamping). In `gateway::packet` the cast lints are allowed
  module-wide instead: those casts move values between libc's C types
  and ours after the value is already known to fit, so fallible
  conversions would only add unreachable branches.
- Signature changes, all on private or crate-internal items except one:
  `RoomRegistry::join` now takes `&EndpointHello` (public, it never
  consumed the hello), `Room::join` and `reject_control_error` likewise.
  `Room`'s `room_id` field is now `id`.
- `#[allow(clippy::too_many_lines)]` with a reason on three end-to-end
  test scenarios and on `bridge_until_shutdown`, whose `select!` loop
  mutates state shared by every arm; splitting it would hide that.
- Mechanical fixes from `cargo clippy --fix`: `map_or_else`, `let...else`,
  inline format args, backticks in doc comments, `Duration::from_mins`.

No runtime behavior changes: the only observable differences are the
error text when a relay room lookup fails immediately after insertion
(previously a panic) and the profile rename described above.

Also documents the lint policy and the profile table in README.md, whose
build section now points at the `just` recipes it should have used all
along.

Test Plan:
- `just clippy` -- passes, zero warnings
- `just test` -- 186 tests pass, 0 failed
- `cargo check --profile production --workspace --all-features` -- passes
- `just fmt` -- clean
- Not verified: the Windows-only code paths and their doc comments, which
  need a Windows target to compile.

Refs: https://doc.rust-lang.org/cargo/reference/profiles.html
Refs: https://rust-lang.github.io/rust-clippy/master/index.html#missing_errors_doc
Refs: https://doc.rust-lang.org/reference/attributes/diagnostics.html#lint-check-attributes
2026-08-16 19:00:54 +02:00
ddidderr 16d0886f36 justfile, AGENTS.md 2026-08-16 10:36:27 +02:00
ddidderr e619866112 feat(client): require explicit TAP selection when ambiguous
Add a Windows client --tap-instance-id option for selecting a specific
TAP-Windows6 adapter by NetCfgInstanceId / InterfaceGuid. The client still opens
the only installed TAP adapter automatically, but now refuses to choose an
arbitrary adapter when multiple TAP-Windows6 adapters are present.

This keeps the MVP test run from silently configuring and opening the wrong TAP
adapter on machines that already have VPN or test TAP devices installed. The
error lists available adapter instance ids so the operator can rerun with the
intended value.

Test Plan:
- cargo fmt --check
- cargo test -p lanparty-client-win
- cargo test --workspace
- cargo clippy --workspace --all-targets -- -D warnings
- git diff --check

Refs: PLAN.md Windows client TAP adapter responsibility
2026-05-21 23:11:01 +02:00
ddidderr bdb571799a feat(net): accept relay hostnames
PLAN.md describes the first client flow as entering a relay domain and room
code, but the client and gateway CLIs only accepted socket-address literals.
Add a small shared RelayEndpoint parser so bare hosts default to UDP/443 while
IP literals and explicit host:port values stay supported.

The runtime configs still store resolved SocketAddr values. That keeps the
Windows route-pinning path on a concrete relay IP before TAP activation while
avoiding duplicated endpoint grammar between client and gateway. The relay
listen config reuses the same default port constant so UDP/443 has one source.

README examples now use lanparty-relay.local and document the shared endpoint
syntax.

Test Plan:
- cargo fmt --check
- cargo test -p lanparty-net
- cargo test -p lanparty-client-win \
  accepts_relay_domain_with_default_port -- --nocapture
- cargo test -p lanparty-gateway \
  accepts_iface_alias_for_gateway_interface -- --nocapture
- cargo test -p lanparty-net -p lanparty-client-win -p lanparty-gateway
- cargo clippy -p lanparty-net -p lanparty-client-win -p lanparty-gateway \
  --all-targets -- -D warnings
- cargo test --workspace
- cargo clippy --workspace --all-targets -- -D warnings
- git diff --check

Refs: PLAN.md
2026-05-21 21:40:00 +02:00
ddidderr 2afdae44c6 feat(client): print runtime diagnostics snapshots
The client now builds ClientDiagnostics snapshots from the connected session,
known TAP state, route-pinning status, and tunnel counters. Windows prints one
snapshot after TAP and relay-route setup, then repeats snapshots while bridging
so frame/datagram counters and drops are visible during manual phase-1 tests.

Non-Windows builds print the same relay and QUIC diagnostics with TAP fields
marked unknown before waiting for Ctrl-C. TAP IP remains unknown until a later
Windows adapter IP inspection slice wires that source of truth.

Test Plan:
- cargo fmt --check
- cargo test -p lanparty-client-win
- cargo clippy -p lanparty-client-win --all-targets -- -D warnings
- cargo test --workspace
- cargo clippy --workspace --all-targets -- -D warnings
- git diff --check

Refs: PLAN.md
2026-05-21 20:16:32 +02:00
ddidderr f88c8a94f8 feat(client): report relay route before TAP activation
Use the new route snapshot helper in the Windows client startup path before the
TAP adapter is opened and marked connected. The client now reports the current
relay destination route: selected source address, next hop, interface index,
interface LUID, route prefix, and metric.

This is still diagnostic only. Route pinning remains unwired, and route lookup
failure is a warning so manual TAP frame-pump testing is not blocked by a route
inspection failure. Once mutation is implemented, this snapshot gives the code
the pre-TAP interface data it needs to preserve the real internet path.

Verification note: I attempted to check `lanparty-client-win` for
`x86_64-pc-windows-msvc`, but this host still lacks the Windows C headers
needed by `ring`; the build stops at `assert.h` before the binary crate can be
typechecked for Windows.

Test Plan:
- cargo fmt --check
- cargo test --workspace
- cargo clippy --workspace --all-targets -- -D warnings
- cargo check -p lanparty-client-route --target x86_64-pc-windows-msvc
- cargo clippy -p lanparty-client-route --target x86_64-pc-windows-msvc -- -D warnings
- git diff --check

Refs: PLAN.md
2026-05-21 19:08:07 +02:00
ddidderr c315add886 feat(client): open TAP adapter on Windows
The client can now reach the relay with a stable virtual MAC, and the TAP crate
can discover and open installed TAP-Windows6 adapters. Wire those pieces
together at startup so the Windows binary opens the first TAP adapter and marks
its media status connected after the relay handshake succeeds.

The binary reports the TAP device path plus the driver MAC and MTU. If those do
not match the tunnel identity or relay-selected MTU, it warns explicitly instead
of pretending configuration is complete.

Frame pumping and route protection remain separate follow-up slices. The full
Windows client binary still cannot be target-checked on this Linux host because
its QUIC/TLS stack needs Windows C headers for ring, but the TAP crate itself is
Windows-target checked and clippy-clean.

Test Plan:
- cargo fmt --check
- cargo test --workspace
- cargo clippy --workspace --all-targets -- -D warnings
- Windows-target cargo clippy for lanparty-client-tap with -D warnings
- git diff --check

Refs: PLAN.md Windows TAP client
2026-05-21 18:50:09 +02:00
ddidderr 93f0a17f79 feat(client): add relay CLI for Windows binary
lanparty-client-win now has a real command-line surface for the relay-facing
client session. It accepts the relay address, expected TLS server name, pinned
DER relay certificate, room code, virtual TAP MAC, and advertised datagram
budget, then connects through lanparty-client-core as role = client.

The binary reports the assigned peer id, room id, and effective TAP MTU from the
welcome response, then waits for Ctrl-C. TAP adapter binding and Windows route
pinning remain future slices, but the executable now exercises the real relay
control-plane path instead of the starter placeholder.

Test Plan:
- cargo fmt --check
- cargo test --workspace
- cargo clippy --workspace --all-targets -- -D warnings

Refs: PLAN.md Windows client relay connection
2026-05-21 18:21:00 +02:00
ddidderr 3c395db3df chore: first project structure 2026-05-21 16:55:51 +02:00